Part Number Hot Search : 
ST10F 2SC57 SP5668KG IW1770 CXOMK ATMEG ELJSC101 TDA98
Product Description
Full Text Search
 

To Download TFS135 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS 135.doc
version 1.5
05.07..2002
VI TELEFILTER
1. Measurement condition
Ambient temperature TA: Input power level: Terminating impedances at fc*: 23 C 0 dBm input: output:
Filter Specification
TFS 135
1/5
1,5 k// -6,0 pF 1,5 k// -5,0 pF
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 135 is the insertion loss. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data Insertion loss (reference level) ae fc ) arel
typ. value 14,5 dB
tolerance / limit max 16,0 dB
Centre frequency (at ambient temperature TA Relative attenuation fc fc fc
-
135,420 MHz
200
kHz
...... fc 1,25 MHz 4 MHz ...... fc 6 MHz 6 MHz ...... fc 15 MHz MHz
35 38 40 dB dB dB
max min min min
3 30 35 38
dB dB dB dB
fc 15 MHz ...... fc 24 Group delay ripple: fc
1,0 MHz
35
ns
max
80
ns
Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T: Operating temperature range Storage temperature range
-19
ppm/K
-
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) - 10 C ... + 85 - 25 C.... + 85 C C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
generated: checked / approved:
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135.doc
version 1.5
05.07..2002
VI TELEFILTER
Filter Specification
TFS 135
2/5
3. Construction, pin configuration and 50 - matching network
(All dimensions in mm)
5.0 SQ -0.1 7 5
+0.15
1 2 3 4 5 6 7 8 Date code: M N P ...... input input ground ground output output ground ground year + week 2000 2001 2002
S 135 P33
1 Date code 3
50 test circuit
LB-IN
C1
1
5
C3
LB-OUT
L1
SAW
2 6
L2
C2
C4
3,4,7,8
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135.doc
version 1.5
05.07..2002
VI TELEFILTER
4. Stability characteristics
1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow):
Filter Specification
TFS 135
3/5
500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
5. Packing
Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po Do D1 E F : : : : : : 12 4 1,5 1,5 0,3 0,1 + 0,5 + 0,5
Do Po
EMBOSSED CARRIER TAPE
P
2
E A
o
1,75 0,1
F
7,5 0,1 0,75 2 8 1,5 5,3 5,3 0,1 0,1 0,05
D 13,4
0,1
1
B
o
W
G (min) : P2 P1 : :
G
0,1
P1
D1(min) : Ao Bo : :
COVER TAPE
Reel (all d im ensions in m m ): A W1 : : 330 12 ,4 + 0 ,2 18 ,4 50 13
W2
W2 (m ax) : N (m in) : C :
+ 0 ,2 / -0 ,5
A
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135.doc
version 1.5
05.07..2002
VI TELEFILTER
6. Air reflow temperature conditions
Filter Specification
TFS 135
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 main-heating periods Cover 200 C 60 sec. - 90 sec. peak temperature 255 C 5 C 20 sec. - 25 sec.
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec.
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
140
160
180
200
220
240
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135.doc
version 1.5
05.07..2002
VI TELEFILTER
Filter Specification
TFS 135
5/5
7. History Version
1.0 1.1
Reason of Changes
generate specification typical values added changing relativ attenuation in stopband terminating impedance added (primary value) terminating impedance changed (preliminary value) changed matching configuration balanced driven
Name
Pfeiffer Pfeiffer
Date
18.09.2001 24.10.2001
1.2 1.3 1.4 1.5.
Pfeiffer Pfeiffer Pfeiffer Pfeiffer
16.11.2001 27.11.2001 14.01.2002 05.07.2002
terminating impedance changed changing relativ attenuation in stopband changing max insertion loss changing range of centre frequency
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS135

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X